VENTURI VALVES
Gate Valves
Gate valves isolate a line with a gate moving perpendicular to the flow. The flow path is largely unobstructed when fully open. They are generally selected for isolation rather than throttling. Metal or resilient sealing, body material and connections must be matched to the medium and operating conditions.
| Valve family | DN | PN / Class | Key selection check |
|---|---|---|---|
| Metal-seated | 50–600 | PN16–160 / Class 150–1500 | Body, trim and actual P–T pair |
| Resilient-seated | 40–600 | PN10–25 | Elastomer–medium compatibility |
| Forged | 15–50 | Class 150–1500 | Distinguish SW / BW / NPT / flanges |
| Knife gate | 50–600 | PN10–16 | Solids, seat and shut-off ΔP |
Ranges describe families. Not every size/rating combination is necessarily available; check each model’s datasheet and selection limits.
Source: Metal Seated Gate Valves · Resilient Seated Gate Valves · Forged Gate Valves · Knife Gate Valves
Sources and scope
Standard links explain scope; they are not product certificates or project approvals. Specify the applicable edition, test scope and acceptance criteria in the purchase specification.
VENTURI VALVES
Let’s specify the right valve.
Tell us the product and how to reach you. Add size, pressure or medium if available; our technical team will help with the selection.