Metal-Seated Gate Valve
DN50–600 metal-seated gate valve family. Compare PN16–160 and Class 150–1500 series, material options, dimensional examples and the original datasheet.
Ranges cover different configurations within the product family. Maximum pressure and temperature do not apply simultaneously; verify the material and pressure–temperature rating for the selected configuration.
01 / Overview
Metal-Seated Gate Valve
A metal-seated gate valve is considered for fully open / fully closed isolation duty. PN and Class options are separate series with different materials, ends and dimensions. DN50–600 on the datasheet cover describes the family, not the availability of every size/rating combination.
Size alone is not enough. We consider medium, temperature, differential pressure, connections and sealing requirements together.
02 / Technical specifications
Technical specifications
| Nominal size | DN50–DN600 |
|---|---|
| Pressure class | PN16–PN160 / Class 150–1500 |
Ranges cover different configurations within the product family. Maximum pressure and temperature do not apply simultaneously; verify the material and pressure–temperature rating for the selected configuration.
Contact Venturi for selection and technical verification against your application requirements.
How is the pressure–temperature limit verified?
PN / Class is a rating designation, not an allowable working pressure at every temperature. Material and temperature notes in the datasheet do not provide a complete pressure–temperature rating table. Obtain approved limits for the actual operating and design conditions, body, trim, gasket and packing. Do not combine maximum pressure and maximum temperature into one operating point.
Source: Venturi — Metal Seated Gate Valves · pp. 03–06 · ASME B16.34 — Valves: Flanged, Threaded and Welding End
Selection and quotation inputs
Provide medium and concentration, minimum / normal / maximum temperatures, operating and design pressures, shut-off differential pressure, DN, end standard, cycling frequency, actuation and required test documents. Distinguish isolation duty from continuous flow control.
Connections and dimensions
The Class-series sheet lists ASME B16.34, B16.10 face-to-face, B16.5 flanges and B16.25 weld ends. Some PN standard entries and the b/n×d rows in Class 900/1500 need clarification. Selected L dimensions are shown here; use an approved drawing for flange drilling and thickness.
| Component / series | Options |
|---|---|
| PN-series body / bonnet | 1.0619 / 1.5419 / 1.7357 / 1.7379 / 1.4308 / 1.4408 |
| Class-series body / bonnet | ASTM A216 WCB / A352 LCB / A217 WC6 / A217 C5 / A351 CF8 |
| Sealing / seat | 13Cr / Stellite |
| Packing | Graphite; configuration dependent |
| Series | DN50 | DN100 | DN200 | DN300 |
|---|---|---|---|---|
| PN16 | 250 | 300 | 400 | 500 |
| PN25 | 250 | 300 | 400 | 500 |
| PN40 | 250 | 350 | 550 | 750 |
| PN63 | 250 | 350 | 550 | 750 |
| PN100 | 250 | 350 | 550 | 750 |
| PN160 | 368 | 450 | 750 | 965 |
| Class 150 | 178 | 229 | 330 | 381 |
| Class 300 | 216 | 305 | 419 | 502 |
| Class 600 | 292 | 432 | 660 | 838 |
| Class 900 | 368 | 457 | 737 | 838 |
| Class 1500 | 368 | 546 | — | — |
For preliminary selection. “—” means no dimension is provided in this table; it does not indicate manufacturing scope or stock. Request an approved general arrangement drawing for the exact end connection, size and rating before installation.
Sources and scope
- Venturi — Metal Seated Gate Valves · pp. 03–06
- ASME B16.34 — Valves: Flanged, Threaded and Welding End
Standard links explain scope; they are not product certificates or project approvals. Specify the applicable edition, test scope and acceptance criteria in the purchase specification.
03 / Applications
Applications
Size alone is not enough. We consider medium, temperature, differential pressure, connections and sealing requirements together.
04 / Downloads
Downloads
Contact us for documentation specific to your application.
Frequently asked questions
What information is needed for a quotation?+
Tell us the product and how to reach you. Add size, pressure or medium if available; our technical team will help with the selection.
Are PN and Class equivalent pressure ratings?+
No. PN and Class are different rating systems. Allowable working pressure depends on the standard, body material and temperature. Do not equate their numerical values.
How is an actuated valve selected?+
Define valve torque or thrust, differential pressure, operating time, control signal and fail position together. Ambient conditions and the required protection rating also affect selection.
Related products
AllVENTURI VALVES
Let’s specify the right valve.
Tell us the product and how to reach you. Add size, pressure or medium if available; our technical team will help with the selection.